Murdoch University Research Repository

Welcome to the Murdoch University Research Repository

The Murdoch University Research Repository is an open access digital collection of research
created by Murdoch University staff, researchers and postgraduate students.

Learn more

Identification of neoplastic cells in blood using the Sysmex XT-2000iV: a preliminary step in the diagnosis of canine leukemia

Gelain, M.E., Rossi, G.ORCID: 0000-0003-4879-9504, Giori, L., Comazzi, S. and Paltrinieri, S. (2010) Identification of neoplastic cells in blood using the Sysmex XT-2000iV: a preliminary step in the diagnosis of canine leukemia. Veterinary Clinical Pathology, 39 (2). pp. 169-179.

Link to Published Version: https://doi.org/10.1111/j.1939-165X.2010.00214.x
*Subscription may be required

Abstract

Background: Classification of leukemias requires specialized diagnostic techniques. Automated preliminary indicators of neoplastic cells in blood would expedite selection of appropriate tests. Objective: The objective of this study was to assess the capacity of the Sysmex XT-2000iV hematology analyzer to identify neoplastic cells in canine blood samples. Methods: Blood samples (n=160) were grouped into 5 categories: acute leukemia (n=30), chronic leukemia (n=15), neoplasia without blood involvement (n=41), non-neoplastic reactive conditions (n=31), and healthy dogs (n=43). WBC counts, WBC flags, scattergrams, percentages of cells with high fluorescence intensity, and percentages of cells in the lysis-resistant region were evaluated alone or in combination to establish a "leukemic flag." Sensitivity, specificity, negative (LR-) and positive (LR+) likelihood ratios, and the number of false-negative (FN) and false-positive (FP) results were calculated, and receiver operating characteristic curves were designed for numerical values. Results: Among single measurements and parameters, only the evaluation of scattergrams minimized FN and FP results (sensitivity 100%, specificity 94.8%, LR+ 19.17, and LR- 0.00), although their interpretation was subjective. The more objective approach based on the generation of a "leukemic flag" had a sensitivity of 100%, specificity of 87.0%, LR- of 0.00, and LR+ of 7.67. Conclusion: Using a novel gating strategy the Sysmex XT-2000iV may be used effectively to screen canine blood for hematopoietic neoplasia.

Item Type: Journal Article
Publisher: American Society for Veterinary Clinical Pathology
Copyright: ©2010 American Society for Veterinary Clinical Pathology.
URI: http://researchrepository.murdoch.edu.au/id/eprint/38949
Item Control Page Item Control Page