Murdoch University Research Repository

Welcome to the Murdoch University Research Repository

The Murdoch University Research Repository is an open access digital collection of research
created by Murdoch University staff, researchers and postgraduate students.

Learn more

Mechanisms underpinning the peak knee flexion moment increase over 2-years following arthroscopic partial meniscectomy

Hall, M., Wrigley, T.V., Metcalf, B.R., Hinman, R.S., Cicuttini, F.M., Dempsey, A.R.ORCID: 0000-0001-8219-6120, Mills, P.M., Lloyd, D.G. and Bennell, K.L. (2015) Mechanisms underpinning the peak knee flexion moment increase over 2-years following arthroscopic partial meniscectomy. Clinical Biomechanics, 30 (10). pp. 1060-1065.

[img]
Preview
PDF - Authors' Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (290kB)
Link to Published Version: http://dx.doi.org/10.1016/j.clinbiomech.2015.09.00...
*Subscription may be required

Abstract

Background
Knee osteoarthritis is common in people who have undergone partial meniscectomy, and a higher external knee flexion moment during gait may be a potential contributor. Although the peak external knee flexion moment has been shown to increase from 3 months to 2 years following partial meniscectomy, mechanisms underpinning the increase in the peak knee flexion moment are unknown.

Methods
Sixty-six participants with partial meniscectomy completed three-dimensional gait (normal and fast pace) and quadriceps strength assessment at baseline (3 months following partial meniscectomy) and again 2 years later. Variables included external knee flexion moment, vertical ground reaction force, knee flexion kinematics, and quadriceps peak torque.

Findings
For normal pace walking, the main significant predictors of change in peak knee flexion moment were an increase in peak vertical ground reaction force (R2 = 0.55), mostly due to an increase in walking speed, and increase in peak knee flexion angle (R2 = 0.19). For fast pace walking, the main significant predictors of change in peak knee flexion moment were an in increase in peak vertical ground reaction force (R2 = 0.51) and increase in knee flexion angle at initial contact (R2 = 0.17). Change in peak vertical force was mostly due to an increase in walking speed.

Interpretation
Findings suggest that increases in vertical ground reaction force and peak knee flexion angle during stance are predominant contributors to the 2-year change in peak knee flexion moment. Future studies are necessary to refine our understanding of joint loading and its determinants following meniscectomy.

Item Type: Journal Article
Murdoch Affiliation(s): School of Psychology and Exercise Science
Publisher: Elsevier
Copyright: Elsevier
URI: http://researchrepository.murdoch.edu.au/id/eprint/29349
Item Control Page Item Control Page

Downloads

Downloads per month over past year