Murdoch University Research Repository

Welcome to the Murdoch University Research Repository

The Murdoch University Research Repository is an open access digital collection of research
created by Murdoch University staff, researchers and postgraduate students.

Learn more

Flow cytometry analysis with a new FITC-Conjugated monoclonal antibody-3E12 for HLA-B*57:01 rapid screening in prevention of abacavir hypersensitivity in HIV-1–infected patients

Rodríguez-Sáinz, C., Valor, L., Hernández, D.C., Gil, J., Carbone, J., Pascual-Bernaldez, M., Rodríguez-Alcántara, F., Martínez, I., Vicario, J.L., Mallal, S. and Fernández-Cruz, E. (2013) Flow cytometry analysis with a new FITC-Conjugated monoclonal antibody-3E12 for HLA-B*57:01 rapid screening in prevention of abacavir hypersensitivity in HIV-1–infected patients. HIV Clinical Trials, 14 (4). pp. 160-164.

Link to Published Version: http://dx.doi.org/10.1310/hct1404-160
*Subscription may be required

Abstract

Background: Rapid screening for the detection of HLA-B*57:01 in the prevention of abacavir hypersensitivity in HIV-1-infected patients is a hallmark for clinical services. Objective: The aim of this work was to analyze the utility of flow cytometry with a new FITC-conjugated B-17 monoclonal antibody (mAb3E12) for HLA-B*57:01 screening in a Spanish cohort of 577 HIV-1+ individuals. Methods: Cryopreserved peripheral blood mononuclear cell samples from HIV-1+ individuals were analyzed by flow cytometry with the mAb 3E12 that recognizes both HLA-B*57 and HLA-B*58 alleles (members of the group specificity, HLA-B17). Patients' DNA samples had been previously typed for HLA-B*57:01 with PCR-SSO or PCR-SSP and additional DNA sequencing (EPI Study). The results obtained by flow cytometry were compared with the results obtained by the DNA-PCR techniques. Results: By flow cytometry, 46 samples (7.97%) were positive for HLA-B17, 530 (91.86%) were negative, and 1 (0.17%) was undetermined. All samples found negative by flow cytometry were negative for HLA-B*57:01 by DNA-PCR. Of the HLA-B17 positive samples, 31 (67.4%) were positive for HLA-B*57:01, 2 (3.25%) were positive for HLA-B*57:03, 11 (26.1%) were positive for HLA-B*58, and 2 (3.25%) were negative for both HLA-B*57 and HLA-B*58 antigens. The undetermined sample was negative for HLA-B*57 and HLA-B*58 alleles by DNA-PCR. Conclusions: This study shows that flow cytometry with mAb3E12 is a highly sensitive method (no false negatives) to implement prior to DNA-PCR analysis for rapid screening of HLA-B*57:01. Additional confirmation by molecular HLA typing method would be required in less than 10% of the cohort of HIV-1-infected individuals.

Item Type: Journal Article
Murdoch Affiliation(s): Institute for Immunology and Infectious Diseases
Publisher: Thomas Land Publishers Inc.
URI: http://researchrepository.murdoch.edu.au/id/eprint/17548
Item Control Page Item Control Page