Commonly applied positive end-expiratory pressures do not prevent functional residual capacity decline in the setting of intra-abdominal hypertension: a pig model

Regli, A., Hockings, L.E., Musk, G.C., Roberts, B., Noffsinger, B., Singh, B. and van Heerden, P.V. (2010) Commonly applied positive end-expiratory pressures do not prevent functional residual capacity decline in the setting of intra-abdominal hypertension: a pig model. Critical Care, 14 (4). R128.

[img]
Preview
PDF - Published Version
Download (356kB) | Preview
    Link to Published Version: http://dx.doi.org/10.1186/cc9095
    *Subscription may be required

    Abstract

    Introduction
    Intra-abdominal hypertension is common in critically ill patients and is associated with increased morbidity and mortality. The optimal ventilation strategy remains unclear in these patients. We examined the effect of positive end-expiratory pressures (PEEP) on functional residual capacity (FRC) and oxygen delivery in a pig model of intra-abdominal hypertension.

    Methods
    Thirteen adult pigs received standardised anaesthesia and ventilation. We randomised three levels of intra-abdominal pressure (3 mmHg (baseline), 18 mmHg, and 26 mmHg) and four commonly applied levels of PEEP (5, 8, 12 and 15 cmH2O). Intra-abdominal pressures were generated by inflating an intra-abdominal balloon. We measured intra-abdominal (bladder) pressure, functional residual capacity, cardiac output, haemoglobin and oxygen saturation, and calculated oxygen delivery.

    Results
    Raised intra-abdominal pressure decreased FRC but did not change cardiac output. PEEP increased FRC at baseline intra-abdominal pressure. The decline in FRC with raised intra-abdominal pressure was partly reversed by PEEP at 18 mmHg intra-abdominal pressure and not at all at 26 mmHg intra-abdominal pressure. PEEP significantly decreased cardiac output and oxygen delivery at baseline and at 26 mmHg intra-abdominal pressure but not at 18 mmHg intra-abdominal pressure.

    Conclusions
    In a pig model of intra-abdominal hypertension, PEEP up to 15 cmH2O did not prevent the FRC decline caused by intra-abdominal hypertension and was associated with reduced oxygen delivery as a consequence of reduced cardiac output. This implies that PEEP levels inferior to the corresponding intra-abdominal pressures cannot be recommended to prevent FRC decline in the setting of intra-abdominal hypertension.

    Publication Type: Journal Article